LED emergency power supply is mainly used to provide backup power supply devices in emergency for all kinds of lamps.

  • Self-contained LED emergency conversion kit (reduced output, 11–20W) for luminaires < 150W under 150W driven by an external isolated driver. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (reduced output, 1–5W) for luminaires under 100W driven by an external isolated driver. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Ni-Cd / Ni-MH / Li-ion / LiFePO4. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.
  • Self-contained LED emergency conversion kit (reduced output, 6–13W) for luminaires < 150W under 150W driven by an external isolated driver. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (reduced output, 16–30W) for luminaires under 150W driven by an external high-power isolated driver. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (reduced output, 31–60W) for high-power luminaires under 150W driven by an external isolated driver. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (reduced output, ≤5W) for luminaires under 100W with high-voltage non-isolated output. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Ni-Cd / Ni-MH / Li-ion / LiFePO4. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (reduced output, 5–15W) for luminaires < 150W under 150W driven by an external isolated driver. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (reduced output, ≤15W) for luminaires < 150W for high-voltage fixtures with non-isolated output. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (reduced output, ≤ 15W) for built-in driven T5 / T8 LED tubes and similar fixtures up to 40W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (low voltage, 11–25W) for low-voltage driven fixtures under 50W (external low-voltage driver). Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (low voltage, 1–10W) for low-voltage driven fixtures under 50W (external low-voltage driver). Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (low voltage, 11–25W) for low-voltage (DC24V / DC36V) driven luminaires under 25W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.
  • Self-contained LED emergency conversion kit (low voltage, 1–10W) for low-voltage (DC24V / DC36V) driven luminaires under 10W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.
  • Self-contained LED emergency conversion kit (full output, 11–20W) for LED lamps with a driving power of 11–25W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (full output, 15–36W) for LED lamps with a driving power of 15–36W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (full output, 37–60W) for LED lamps with a driving power of 37–60W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (full output, 61–150W) for LED lamps with a driving power of 61–150W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (full output, 151–200W) for LED lamps with a driving power of 151–200W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Self-contained LED emergency conversion kit (full output, ≤ 10W) for low-power LED lamps within 10W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.
  • Self-contained LED emergency conversion kit (full output, 11–15W) for LED lamps with a driving power of 11–15W. Transfer < 1 s; emergency time 1H/1.5H/2H/3H or custom; Maintained / Non-maintained; battery options Li-ion / LiFePO4 / Ni-Cd. Built to EN/IEC 61347-2-7 & EN/IEC 60598-2-22; CE / CB / RoHS. Inquiry only — contact us for pricing.

  • Fuerten LED Emergency Conversion Kits

    The kit can output 3~10W emergency power, battery for 1.5h~3.0hours duration and indiaction LED.

    This kit is compatible with most widely used LED lamp within 100W power Lamp. Meanwhile, the kit will continuously and steadily provide an emergency backup power when main power lose the function.

    Prodcuts name:Fuerten full power conversion kit  Model name: FT168T Main Supply: 220V~240V AC 50/60Hz Work Power Rating: Max:100W Duration:90~180mins Recharge Period: 24 hours Battery  Type: 7.2V NiCd, 7.4V Li-ion, 6.4V LiFePo4 Battery Charging Current: 200mA Kit weight: 0.5Kg
  • Fuerten LED Emergency Conversion Kits

    The kit can output 2~5W emergency power, battery for 1.5h~3.0hours duration and indiaction LED.

    This kit is compatible with most widely used LED lamp within 40W power. Meanwhile, the kit will continuously and steadily provide an emergency backup power when main power lose the function.

    Prodcuts name:Fuerten full power conversion kit  Model name: FT268C Main Supply: 220V~240V AC 50/60Hz Power Rating: Max:40W Duration:90~180mins Recharge Period: 24 hours Battery  Type: 3.6V NiCd Battery Charging Current: 200mA Kit weight: 0.4Kg
  • Fuerten LED Emergency Conversion Kits

    The kit can output 100% emergency power as to your main power time.

    This kit is compatible with most widely used LED lamp within 24W power. Meanwhile, the kit will continuously and steadily provide an emergency backup power when main power lose the function.

    Prodcuts name:Fuerten full power conversion kit  Model name: FT168H-F2424180 Main Supply: 220V~240V AC 50/60Hz Power Rating: Max:24W, 109mA Duration:180mins Recharge Period: 24 hours Battery Size & Type: 11.1V 8.8Ah, Lithium Battery Charging Current: 200mA Kit weight: 0.8Kg
  • 促销中

    LED Tube Emergency Conversion Kits-18W 180MINS

    原价为:$22.50。当前价格为:$21.00。

    Fuerten LED Emergency Conversion Kits

    This kit is used specialized on 18W LED Tube with 100% emergency power 18W 180mins steadily emergency power output. Very commonly use and big stock for fast shipment. 

      Prodcuts name:Fuerten full power conversion kit  Model name: FT168H-F1818180 Main Supply: 220V~240V AC 50/60Hz Power Rating: 18W Duration:180mins Recharge Period: 24 hours Battery Size & Type: 11.1V 8.8Ah, Lithium Battery Charging Current: 200mA Kit weight: 0.8Kg